ASCO Power Technologies Products Digital Binder

WITHSTAND AND CLOSING RATINGS Withstand and Close-on Ratings for all 7000 SERIES Power Transfer Switches, including 0.5 second (30-cycle) designs.

Series 300 Transfer Switch Dimensions and Shipping Weights (Type 3R)

DIMENSIONS, IN. (MM) 2

SWITCH RATING AMPS

PHASE POLES

APPROX. SHIPPING WEIGHT LB.

NEUTRAL CODE 1

Short Time Ratings 1 (sec)

Switch Rating (Amps)

Current Limiting Fuses

Specific Breaker

Time Based

WIDTH

HEIGHT

DEPTH

Frame

480V Max.

600V Max.

Transfer Switches

2 2 3 3 2 2 3 3 2 2 3 3 2 2 3 3 2 2 3 3 2 2 3 3 2 2 3 3 3 3 3 3

A B A B A B A B A B A B A B A B A B A B A B A B A B A B A B A B

18 18 18 18 18 18 18 18 24 24 24 24 24 24 24 24 24 24 24 24 34 34 34 34 41 41 41 41 41 41 41 41

35 35 35 35 35 35 35 35 64 64 64 64 64 64 64 64 64 64 64 64 75 75 75 75 96 96 96 96 96 96 74 74

14 14 14 14 14 14 14 14 18 18 18 18 18 18 18 18 18 18 18 18 20 20 20 20 33 33 33 33 62 62 96 96

86 88 88 90 86 88 88 90

Bypass Switches

480V Max.

600V Max.

Max Size, A

240V Max.

480V Max.

600V Max.

Time (sec)

240V Max.

480V Max.

600V Max.

0.13 0.2 0.3 0.5 0.1 0.13 0.3 0.5

Class

30 3 ,70 3 ,104 3 150 3 , 200 3

100kA -

300

J J

10kA 10kA

-

-

D

30

-

22kA 22kA 10kA 0.025 10kA

200kA 35kA 200 35kA 35kA 200 35kA 35kA 200 200kA 35kA 200 35kA 35kA 200 200kA 35kA 200 200kA 35kA 200 35kA 35kA 200

RK1 RK1

10kA

-

D

150kA

10kA

85kA 25kA

10kA

0.025

-

70, 100

-

J

RK1

D

150kA 85kA

25kA

0.025

10kA 10kA 10kA

-

-

150

-

J

J

-

-

200kA 85kA 14kA 0.025 10kA 10kA 10kA

D

200

-

230

RK1

-

-

100kA -

200kA 85kA 14kA 0.025 10kA 10kA

-

D

230

-

300 600 800 600 800

J J L J L L J L L L L L L L L

65kA 42kA 2

J

200kA 200kA 42kA 0.05

35kA 7.5kA

-

-

150, 200, 260 150, 200, 230, 260 200kA 200kA

206 206 212 218 222 222 228 224 247 247 234 241 560 576 576 580 717 717 717 717

0.05 65kA 42kA 2 65kA 65kA 85kA 42kA 0.05 65kA 42kA 2 50kA 42kA

J

-

35kA

7.5kA 3 7.5kA

-

400

400

200kA 200kA

200kA 200kA 800 200kA 200kA 600 200kA 200kA 1600 200kA 200kA 1600 5 200kA 200kA 2000 200kA 200kA 2500 200kA 200kA 3000 200kA 200kA 4000

260, 400

J

35kA

-

-

600 600

600 600

42kA 42kA 42kA 36kA 36kA

36kA 36kA

H 4

65kA 150kA 65kA 0.05 50kA 50kA 50kA 65kA 150kA 65kA 0.05 50kA 50kA 50kA 85kA 85kA 85kA 0.05 85kA 85kA 85kA 85kA 85kA 85kA 0.05 85kA 85kA 85kA 200kA 200kA 100kA0.05 100kA 100kA 100kA 125kA 125kA 100kA 0.05 100kA 100kA 100kA 6 6

- -

- -

H

800 - 1200 1000 - 1200

800 - 1200 1000 - 1200 1600 - 2000 2600 - 3000

-

- -

G 4

1600 - 2000 (Front Connected TS Only)

36kA 36kA 36kA

G

42kA 42kA

G 4

1600 - 2000

- -

150, 200, 230 SERIES 3ADTS/3NTS only

G 2600 - 3000

-

65kA -

G 4

3200 4000

-

200kA -

4000

100kA 100kA -

0.05 100kA 100kA -

65kA

4000

G

200kA 200kA 5000

100kA 100kA 100kA 0.05 100kA 100kA 100kA 85KA

Notes: 1. All WCR values indicated are tested in accordance with the requirements of UL 1008, 7th Edition. See ASCO Pub. 1128 for more WCR information 2. Application requirements may permit higher WCR for certain switch sizes. 3. Short Time ratings are provided for applications involving circuit breakers that utilize trip delay settings for system selective coordination 4. Max fuse rating is 1200A on front connected H frame switches 5. Switches utilizing overlapping neutral (code "C") have 35kA, 0.050 Sec time based rating at 480V Max 6. Rating shown is for Bypass switches only, Transfer Switch rating is 100kA for the G frame and 65kA max for the H and P frames. See ASCO Pub. 1128. 7. See ASCO for Service Entrance Switch ratings 8. These frames are only available on the 7000 Series product 9. Short Time Rating applies to 600A Bypass switch only, the 600A Transfer Switch does not have a Short Time Rating All units are RMS Symmetrical Amperes. All Withstand and Close-on Rating (WCR) values are established by testing in accordance with UL 1008. For the latest ratings, including transfer switch ratings when used with specific circuit breakers, see ASCO Publication 1128 for more WCR information. Application characteristics may permit higher WCRs for certain switch sizes.

600 ( Non-Secure Enclosure)

800, 1000 ( Non-Secure Enclosure)

1200 ( Secure Enclosure)

1700 1700 2150 2230

1600, 2000 ( Secure Enclosure)

2600, 3000 ( Secure Enclosure)

EXTENDED WARRANTIES FOR SERIES 300 TRANSFER SWITCHES (3ATS/3NTS/3ADTS/3NDTS)

Notes: When climate conditions at installation site present condensation risk, special precautions should be taken, such as the inclusion of space heaters, to prevent interior condensation and freezing of this condensation. 1. Neutral Codes: A=Solid, B=Switched 2. Dimensional data is approximate and subject to change. Certified dimensions available upon request. 3. Dimensions for 30-200 ampere models when furnished with a power meter are 18"W x 48"H x 13"D.

DESCRIPTION

1 Year Extension (Total of 3 Years) 2 Year Extension (Total of 4 Years) 3 Year Extension (Total of 5 Years)

Notes: Standard warranty is (24) months, 2 years from date of shipment, extended warranty is in addition to the two years, for a total of, 3, 4, or 5 years. Refer to Publication 3223 for warranty terms and conditions.

For more details, please contact customercare@ascopower.com