Specifications

ASCO SERIES 300SE Power Transfer Switch Dimensions and Shipping Weights

UL Type 1 Enclosure 4

UL Type 3R Enclosure 4

Dimensions, In. (mm)

Dimensions, In. (mm)

Switch Rating Amps

Phase Poles

Neutral Code

Approx. Shipping Weight Lb. (kg)

Switch Rating Amps

Phase Poles

Neutral Code

Approx. Shipping Weight Lb. (kg)

Width

Height

Depth

Width

Height

Depth

2 2 3 3 2 2 3 3 2 2 3 3 2 2 3 3 2 2 3 3 2 2 3 3 3 3 3 3

A B A B A B A B A B A B A B A B A B A B A B A B A B A B

36 (914) 36 (914) 36 (914) 36 (914) 36 (914) 36 (914) 36 (914) 36 (914) 42 (1067) 42 (1067) 42 (1067) 42 (1067) 38 (965) 38 (965) 38 (965) 38 (965) 38 (965) 38 (965) 38 (965) 38 (965) 38 (965) 38 (965) 38 (965) 38 (965) 38 (965) 38 (965) 38 (965) 38 (965)

48 (1219) 48 (1219) 48 (1219) 48 (1219) 48 (1219) 48 (1219) 48 (1219) 48 (1219) 48 (1219) 48 (1219) 48 (1219) 48 (1219) 91 (2311) 91 (2311) 91 (2311) 91 (2311) 91 (2311) 91 (2311) 91 (2311) 91 (2311) 91 (2311) 91 (2311) 91 (2311) 91 (2311) 91 (2311) 91 (2311) 91 (2311) 91 (2311)

13 (330) 13 (330) 13 (330) 13 (330) 13 (330) 13 (330) 13 (330) 13 (330)

400 (185) 410 (189) 410 (189) 430 (198) 400 (185) 408 (188) 408 (188) 420 (193) 420 (193) 430 (198) 430 (198) 450 (207) 860 (396) 870 (401) 870 (401) 880 (405) 1460 (673) 1470 (677) 1470 (677) 1480 (682) 1460 (673) 1470 (677) 1470 (677) 1480 (682) 1580 (727) 1680 (773) 4590 (2111) 4690 (2157)

2 2 3 3 2 2 3 3 2 2 3 3 2 2 3 3 2 2 3 3 2 2 3 3 3 3 3 3

A B A B A B A B A B A B A B A B A B A B A B A B A B A B

36 (914) 36 (914) 36 (914) 36 (914) 41 (1041) 41 (1041) 41 (1041) 41 (1041) 42 (1067) 42 (1067) 42 (1067) 42 (1067) 41 (1041) 41 (1041) 41 (1041) 41 (1041) 38 (965) 38 (965) 38 (965) 38 (965) 38 (965) 38 (965) 38 (965) 38 (965) 38 (965) 38 (965) 38 (965) 38 (965)

48 (1219) 48 (1219) 48 (1219) 48 (1219) 95.5 (2424) 95.5 (2424) 95.5 (2424) 95.5 (2424) 48 (1219) 48 (1219) 48 (1219) 48 (1219) 95.5 (2425) 95.5 (2425) 95.5 (2425) 95.5 (2425) 91 (2311) 91 (2311) 91 (2311) 91 (2311) 91 (2311) 91 (2311) 91 (2311) 91 (2311) 91 (2311) 91 (2311) 91 (2311) 91 (2311)

16 (406) 16 (406) 16 (406) 16 (406) 33 (838) 33 (838) 33 (838) 33 (838) 18 (487) 18 (487) 18 (487) 18 (487) 33 (838) 33 (838) 33 (838) 33 (838) 28 (711) 28 (711) 28 (711) 28 (711) 48 (1218) 48 (1218) 48 (1218) 48 (1218) 48 (1218) 48 (1218) 72 (1829) 72 (1829)

500 (232) 520 (241) 520 (241) 530 (246) 500 (232) 520 (241) 520 (241) 530 (246) 500 (232) 520 (241) 520 (241) 530 (246) 1200 (555) 1220 (564) 1220 (564) 1240 (574) 1520 (703) 1540 (712) 1540 (712) 1580 (731) 1520 (703) 1540 (712) 1540 (712) 1580 (731) 2200 (1018) 2240 (1036) 5280 (2479) 5380 (2475)

70, 100, 150, 200, 225

70, 100, 150, 200, 225

150, 200, 225, S eries 3ADUS/3NDUS Only

150, 200, 225, S eries 3ADUS/3NDUS Only

15.5 (394) 15.5 (394) 15.5 (394) 15.5 (394) 28 (711) 28 (711) 28 (711) 28 (711) 28 (711) 28 (711) 28 (711) 28 (711) 48 (1218) 48 (1218) 48 (1218) 48 (1218) 48 (1218) 48 (1218) 72 (1829) 72 (1829)

2501, 4001

2501, 4001

6001

6001

8001

8001

10001, 12001

10001, 12001

16001, 20001

16001, 20001

25001, 30001

25001, 30001

Notes: 1. Unit is designed for top and bottom cable entry for all services and load. 2. Enclosures for 600 – 3000 amps are freestanding.

3. A space heater accessory 44G is required with all service entrance (Type 3R) switches to help reduce condensation and protect the circuit breaker. It is recommended when environmental enclosures (Type 4, 12) are ordered for installation outdoors. See Optional Accessories page for space heater options (acc. 44G). 4. Dimensional data is approximate and subject to change. Certified dimensions available upon request.

Extended Warranties for S eries 300SE Transfer Switches (3AUS/3NUS/3ADUS/3NDUS)

S eries 300SE External Power Connections Sizes UL-Listed Solderless Screw-Type Terminals

Description 1 Year Extension (Total of 3 Years) 2 Year Extension (Total of 4 Years) 3 Year Extension (Total of 5 Years)

Switch Rating

Ranges of AL-CU Wire Sizes

70, 100, 150, 200 2 , 225 2

One #14 to 4/0 AWG

150 3 , 200 3 , 225 3 , 250, 400

One #4 AWG to 600 MCM Two 1/0 to 250 MCM Two 1/0 to 600 MCM Four 1/0 to 600 MCM Six 1/0 to 600 MCM Twelve 3/0 to 750 MCM Twelve 3/0 to 750 MCM

600

Notes:

1. Standard warranty is (24) months, 2 years from date of shipment, extended warranty is in addi tion to the two years, for a total of 3, 4 or 5 years, except where the warranty period for the circuit breaker shall be limited to 24 months from date of shipment from ASCO. 2. Refer to Publication 3223 for warranty terms and conditions.

800, 1000, 1200

1600, 2000

2500 3000

S eries 300SE AIC Breaker Rating 1

Notes: 1. All S eries 300SE switches are furnished with a solid neutral plate (unless switched neutral configuration is specified) and terminal lugs. 2. 200 and 225 ampere rated switches for use with copper cable only. Refer to paragraph 310.15 of the NEC for all additional information. 3. J 150-225 ampere for S eries 3ADUS/3NDUS only. 4. Use wire rated 75 degrees minimum for all power connections.

Switch Rating

AIC Rating (KA)

Voltage

70, 100, 150, 200, 225

25,000

480

150, 200, 225 S eries 3ADUS/3NDUS Only

35,000

480

35,000 65,000 50,000 65,000 100,000

480 480 480 480 480

250, 400, 600

5. Refer to the outline drawing for maximum power cable connections for circuit breaker.

800

1000, 1200 1600, 2000 2500, 3000

Notes: 1. Refer to S eries 300 Publication 1195 for switch ratings.

ASCO Power Technologies 160 Park Avenue, Florham Park, NJ 07932

www.ascopower.com customercare@ascopower.com 1-800-800-ASCO (2726) © 2022 Publication 2007 R4