ASCO Power Technologies Products Digital Binder
Order Information
J
04ATE
A
3 0200
B
H
X
C
Frame
Type
Neutral
Poles
Amps
Voltage
Controller Accessories
Enclosure
J
04ATE - Automatic Open Transition 04NTE - Non-Automatic Open Transition 4ADTE - Automatic Delayed Transition 4NDTE - Non-Automatic Delayed Transition
A - Solid B - Switched Blank - None
2 3
0150 0200 0230 0260 0400 0600
A - 115 B - 120 C - 208 D - 220 E - 230 F - 240 G - 277 H - 380 J - 400
K - 415 L - 440 M - 460 N - 480 P - 550 Q - 575 R - 600
H - Group H 0 - No X- Yes
0 - Open Type C - Type 1
M - Type 3R Secure N - Type 4 Secure P - Type 4X Secure (204) SS
Q - Type 12 V - Type 4X Secure (316) SS
Lug Details
Ampacity Range of Conductor Sizes 150
Additional Features and Qualifications 2 sets of ATS position contacts standard
(Qty 2) 1/0 - 250 MCM or (Qty 1) #4 - 600MCM (Qty 2) 1/0 - 250 MCM or (Qty 1) #4 - 600MCM (Qty 2) 1/0 - 250 MCM or (Qty 1) #4 - 600MCM (Qty 2) 1/0 - 250 MCM or (Qty 1) #4 - 600MCM (Qty 2) 1/0 - 250 MCM or (Qty 1) #4 - 600MCM
200 230 260 400 600
Interlocking prevents improper operation of equipment Complies to UL 1008 for Transfer Switch Equipment Applicable in NEC Ar ticle 700, 701, and 702 systems Meets requirements of NFPA 110 (Standard for Emergency and Standby Power System)
(Qty 1) #2 - 600MCM
Key Optional Accessories
Code Description 1GB1 Provisions for customer supplied 120VAC power to enable communications during an extended dual-source outage 1UP Capacitor backup module to provide 11 seconds minimum of power for communication while waiting for generator star t 7ES Provisions for engine star t signal integrity monitoring system. (Require additional 5101-Gen module at generator) 14A1 / 14B1 Auxiliary contact that closes when switch is bypassed to the normal source / emergency source 14U / 14V Auxiliary contact that closes when the TS rack is in the connected position / isolate position 18RX REX module to provide source acceptability status contacts, additional multipurpose output (OP), and provisions for a customer 24VDC auxiliary control power 23GA / 23GB Load current metering provided via Group H Controller (Provides current only) 30A Provisions for a customer supplied contact that will immediately shed the switch off the emergency source when opened 30B3 Provisions for a customer supplied 24VDC signal that will immediately shed the switch off the emergency source voltage is removed 72EE ASCO Ethernet Communication module to provide Modbus TCP/IP, e-mail alarming, web page, and additional remote monitoring options 73 Internally mounted surge suppressor (Models vary by specification, contact ASCO for details) 135L 5210 Digital Power Meter monitoring the load side of the switch (Provides VLL, VLN, I, kW, kVA, kVAr, THD, and Demand) 150E Tech Bundle - Ethernet Communication Module (72EE), Capacitor backup module (1UP), and Power Metering on the load (135L)