ASCO Power Technologies Products Digital Binder
ASCO 7000 S ERIES DESIGNED TO FIT ANYWHERE Automatic Transfer Switching – Open Transition: 7ATS and 7NTS Dimensions and Shipping Weights*
Switch Ratings Amp
Neutral Type & Poles 02 or A2 03 or A3 B3 or C3 02 or A2 03 or A3 B3 or C3 02 or A2 03 or A3 B3 or C3 02 or A2 03 or A3 B3 or C3 02 or A2 03 or A3 B3 or C3 02 or A2 03 or A3 B3 or C3 02 or A2 03 or A3 B3 or C3 02 or A2 03 or A3 B3 or C3 02 or A2 03 or A3 B3 or C3 02 or A2 03 or A3 B3 or C3
Type 1 Enclosure 1
Open Switch Configuration
Frame
Width In (mm)
Height In (mm)
Depth In (mm)
Weight lb (kg) 70 (32) 80 (36) 85 (39) 115 (52) 120 (55) 130 (59) 270 (123) 280 (128) 290 (132) 270 (123) 280 (128) 290 (132) 470 (214) 480 (219) 490 (223) 670 (308) 680 (310) 690 (315) 1330 (606) 1350 (616) 1400 (638) 1300 (590) 1345 (612) 1390 (635) 2150 (980) 2180 (994) 2230 (1017) 2250 (1026) 2280 (1040) 2330 (1062)
Width In (mm)
Height In (mm)
Depth In (mm)
Open 2 lb (kg) 30 (14) 35 (16) 40 (18) 35 (16) 40 (18) 45 (21)
D
30, 70, 100
18 (457) 48 (1219) 13 (330)
10 (260)
10 (260) 5.5 (140)
D 150, 200, 230
18 (457) 48 (1219) 13 (330)
10 (260)
10 (260) 5.5 (140)
220 (100) 230 (105) 240 (109) 260 (119) 270 (123) 280 (128) 260 (119) 270 (123) 280 (128) 300 (137) 310 (141) 320 (146) 450 (205) 470 (214) 500 (228) 450 (205) 470 (214) 500 (228) 890 (406) 920 (420) 1000 (456) 990 (451) 1020 (465) 1100 (502)
J
150, 260, 400
24 (610) 56 (1422) 14 (356)
19 (470)
25 (635)
8 (203)
J
600
24 (610) 63 (1600) 17 (432)
19 (470)
30 (762)
10 (251)
H 600, 800, 1000
34 (864) 72 (1829) 20 (508)
27 (686)
31 (787)
13 (327)
H
1200
38 (965) 87 (2210) 23 (584)
27 (686)
31 (787)
13 (327)
G 1000, 1600 3 , 2000 3
38 (965) 91 (2311) 48 (1219)
33 (845)
28 (711)
26 (667)
1600, 2000 (Front Connected) 4
G
38 (965) 87 (2210) 23(584)
33 (845)
28 (711)
26 (667)
G 2600 3 , 3000 3
38 (965) 91 (2311) 60 (1524)
33 (845)
29 (711)
31 (781)
60 (1524)
G
4000 3
92 (2311) 72 (1829)
60 (1524) 70 (1778) 53 (1272)
Notes: 1. Consult ASCO for dimensions on enclosures other than UL type 1. 2. Open weights include transfer switch and controller. 1200-4000 amp enclosures require ventilation openings, refer to drawing for details. 3. Enclosures are free-standing with removable top, sides, and back. 4. Order accessory 40MY for 1600A and 40NY for 2000A Front Connected (F/C) design.
*All dimensions and weights shown are approximate and should not be used for construction purposes. Verified dimensions can be furnished upon request.
4
Made with FlippingBook - Online catalogs