ASCO Power Technologies Products Digital Binder
ASCO SERIES 300 Manual Transfer Switch with Dual Purpose Quick Connects
ASCO SERIES 300 MTDQ
ASCO SERIES 300 MGDQ
UTILITY
UTILITY
SOURCE 1
SOURCE 1
SOURCE 2
SOURCE 2
LOAD
LOAD
Permanent Gen Breaker
Permanent Gen Breaker
TO LOAD
TO LOAD
TO MTDQ
TO MGDQ
E L N
E L N
Permanent Generator
Permanent Generator
Female Camlocks
Female Camlocks
Male Camlocks
Male Camlocks
(Load Bank Connection)
(Load Bank Connection)
ASCO 7000 SERIES Bypass Switch
ASCO 7000 SERIES Bypass Switch
Temporary Generator
Temporary Generator
Catalog Information 3QC
3MTDQ
A
3
0600
N
0X
M
Phase Poles
Voltage Code
Group Code
Frame
Product
Neutral Code
Amperes
Enclosure
J = 150 - 600A
3MTDQ - Manual Transfer Switch with Dual Quick Connects 3MGDQ - Manual Transfer Switch with Dual Quick Connects and Portable Generator breaker
A - Solid Neutral
2 3
0150 0200 0225 0250 0400 0600 0800 1000 1200 1600 2000 2500 3000
C - 208 D - 220 E - 230 F - 240 H - 380 J - 400 K - 415 L - 440 M - 460 N - 480 P - 550 Q - 575 R - 600
00 - No Accessory
M - Type 3R Secure
H = 800 - 1200A
S - Type 3RX Secure (316) SS
B - Switched Neutral
0X - Accessory
G = 1600 - 3000A
0Z - Custom Accessory
ASCO 171 MTDQ & MGDQ User Interface/Annunciation Accessories 171 B P
1
Accessory Description
User Interface/Controls
Phase Rotation
IO Module
B – Base (Source Indication Only. No engine start switch or common alarm) E – Maintained Engine Start Switch/ Output With Common Alarm Input/ LED/Contact K – Keyed Maintained Engine Start Switch/Output with Common Alarm Input/LED/Contact
P = Phase Rotation Monitor (LED)
1 = IO Module
All 171 Accessories Include LEDs and Contacts For:
Blank = none
Blank = None
• Source 1 Available • Source 2 Available
• Connected to Source 1 • Connected to Source 2 • Disconnected Position • Load Bank Connection
Additional ASCO MTDQ & MGDQ Accessories
Accessories Description 44A Strip heater with thermostat prevent condensation and ice formation of water. External 120V power source required
44G Strip heater with thermostat wired to load terminals 72EE Connectivity module provides remote monitoring 73 Surge Suppressor Rated 65kA 135L Power Meter on Load Side (includes shorting block and current transformers)
ASCO Power Technologies 160 Park Avenue, Florham Park, NJ 07932
www.ascopower.com customercare@ascopower.com 1-800-800-ASCO (2726) © 2024, R3. Publication 2079
Made with FlippingBook - Online catalogs